The application of electric welding mesh is more widely, at present, it has replaced the use of other parts of the screen, the cost of electric welding mesh is low, the production speed is very fast, so it is very popular. The treatment required before galvanized welding mesh is recrystallization annealing, because the welding mesh must maintain an oxide and no other impurities of pure iron active surface, if you can’t keep its surface clean will lead to poor galvanized effect, galvanized layer and iron material is not tightly combined, so this step is necessary.
Galvanized wire is divided into hot dip galvanized iron wire and galvanized iron wire according to the production process. It has the characteristics of high tensile strength, good softness, zinc layer uniformity, corrosion resistance, beautiful color, good smoothness, strong adhesion and corrosion resistance. Hot dip galvanizing has better protective properties than electric galvanizing, so it is an important protective coating for steel parts used in harsh working conditions.
Purpose of galvanized hexagonal net: building wall fixed, heat preservation, heat insulation; Power plant tied pipe, boiler warm; Anti-freezing, residential protection, landscaping protection; Raising chickens and ducks, isolating chicken and duck houses, to protect poultry; To protect and support seawalls, hillsides, roads and Bridges and other waterworks.
In the purchase of large rolls of galvanized wire, see the hardness of galvanized wire first, only after the hardness reaches the standard can be used. The hardness standard of large roll galvanized wire is a very important performance index and an economic test method. But for the hardness of metal materials, there is not a unified and clear definition including all test methods at home and abroad.
Each coil of steel wire shall consist of one wire. The surface of the rod shall not have cracks, folds, scars, ears, layers or inclusions. However, indentation, pits, bumps, scratches and pockmarks are allowed, and the depth or height shall not be 0.2mm. There should be no corrosion and oxidation skin on the surface of the steel wire, and oxidation color is allowed by heat treatment. The surface of the wire is allowed to have scratches not exceeding half of the allowable deviation range of the diameter, and local defects not exceeding the allowable deviation of the appropriate diameter.
When the temperature is running at the same temperature and the same heat is stored, the amount of iron dissolved is not the same. At around 500, the loss of iron increases sharply with the addition of temperature and insulation. It is lower or higher than 480~ 510c, and the loss of epitaxial iron is slower, and it is difficult to catch up with the duration. Therefore, everyone will call 480~ 510c the malignant melting zone.The construction of inner wall and outer wall steel wire mesh can effectively solve the wall cracks, falling off, empty drum phenomenon. Hot dip galvanized steel wire mesh material requirements: net surface leveling, width and length to meet the project required standards, welding process, weight, zinc, etc., with more production and operation, detection certificate is complete.
There are two varieties of steel grid plate is pressure welded steel grid plate and pressure lock steel grid plate, in many people’s eyes, these two products belong to the same variety, in fact, there are still great differences between them in many places.
After annealing, the extension rate of galvanized wire is increased, making the product more soft and increasing the scope of application of galvanized wire. After electric galvanized hot galvanized, electroplated copper and other widely used screen production. Building reinforcement binding with galvanized wire mesh braided with the first after plating, plating and other methods, after treatment of galvanized wire mesh or steel wire mesh, has good corrosion resistance, oxidation resistance characteristics, can be used in construction, petroleum, chemical, aquaculture, garden protection, food processing and other industries reinforcement, protection and heat preservation.
Raw material of wire mesh sheet cold drawn low carbon steel wire base material can choose low carbon steel hot rolled disk bar or hot rolled smooth steel bar. The base material number and diameter of cold-drawn low carbon steel wire can be confirmed according to the rules in the table below. During the cold drawing process, the surface shrinkage rate of each drawing should not be greater than the wire mesh before cold drawing. Annealing shall not be carried out during wire drawing. If butt welding is required, the same production unit and base material of the same number should be selected. The appearance quality of wire mesh should not affect wire drawing. When the welding function is poor or brittle fracture occurs, special inspection should be carried out according to relevant standards.
Some large roll galvanized wire products in order to meet different industrial needs, will be further processed on the surface, such as the anti-corrosion layer, galvanized, iron plating, aluminum alloy plating, or in the galvanized wire appearance above the copper plating, brass plating, etc., to strengthen the steel wire and colloidal years and capabilities. Generally, galvanized wire products should be well plated and drawn when they are produced, and the sequence of the two processes should be decided according to the production or industrial needs.
This method is generally the use of hot rolled laminated plate as raw material, the annealed steel plate is first sent to the pickling workshop, with sulfuric acid or hydrochloric acid to remove the surface of the steel sheet oxygen hot galvanizing method. After pickling, the steel plate immediately enters the tank to soak and wait for galvanized, which can prevent the reoxidation of the steel plate. After pickling, water cleaning, squeeze dry, drying, into the zinc pot, the temperature has been maintained at 445-465℃.
It’s not clear why friends would want to use building nets for floor heating. What are its advantages in the floor heating project, the role of steel wire mesh is convenient for construction. Building mesh can better fix the pipe, conducive to the construction of the floor, improve efficiency. Anti crack function. The building network can improve the bearing capacity of the foundation of the thermal insulation board, the thicker the diameter of the steel wire of the building, the greater the bearing capacity, effectively prevent the appearance of cracks and cracks of steel wire mesh can improve the thermal shrinkage and contraction of cement, strengthen the tensile strength of cement, improve the quality of the heating project.