Stainless steel barbed rope in the way of corrosion is not very, because the surface is not treated but rely on its own raw materials for corrosion resistance, so there will be no chemical reaction.
The corrosion or discoloration of galvanized iron wire in the atmosphere caused by oxygen, moisture and other pollution impurities is called rust or rust. After galvanized iron wire rusting, it will affect the appearance quality, seriously affect the use, and even cause scrap, so galvanized iron wire must be properly kept and pay attention to rust prevention.
3, reduce the bivalent iron ion in the plating aid used for hot plating wire, reduce the formation of zinc slag
Friends in the industry know that galvanized iron wire has two kinds of cold galvanized iron wire and hot galvanized iron wire, so what is the difference between cold galvanized iron wire and hot galvanized iron wire? Which is good?
Hot dip galvanized steel wire surface smooth, smooth, no cracks, joints, thorns, scars and corrosion, galvanized layer uniform, strong adhesion, corrosion resistance lasting, toughness and elasticity is excellent. The tensile strength should be between 900Mpa-2200Mpa (wire diameter Φ0.2mm-Φ4.4mm). The number of torsion (Φ0.5mm) in more than 20 times, repeated bending should be more than 13 times. The thickness of galvanizing is thin, usually only 3-15 microns, bright, smooth, beautiful appearance, poor corrosion resistance, generally a few months will rust.Different supports are used for different installation environments. In the past, the blade barbed wire was not easy to fix, and the installation environment was often steep. Therefore, special tools must be used to fix the blade barbed wire to prevent it from being improperly installed.
In the corner area, the zinc layer is often thicker than other places, and has good toughness and abrasion resistance. And other coatings in this corner, often Z thin Z is not easy to construction, Z is easy to hurt, so often need to be maintained. Even if there’s a lot of mechanical damage or something. Causing a small layer of zinc to peel off, leaving the iron base exposed, the surrounding zinc layer will act as a sacrificial anode to protect the steel from erosion.Some large roll galvanized wire products in order to meet different industrial needs, will be further processed on the surface, such as the anti-corrosion layer, galvanized, iron plating, aluminum alloy plating, or in the galvanized wire appearance above the copper plating, brass plating, etc., to strengthen the steel wire and colloidal years and capabilities. Generally, galvanized wire products should be well plated and drawn when they are produced, and the sequence of the two processes should be decided according to the production or industrial needs.
The wire used for wire mesh is made of low carbon steel wire, medium carbon steel wire, high carbon steel wire, stainless steel wire and other materials woven or welded. Production technology: general braid, embossed braid and spot welding type. If the steel wire as the material, after the equipment processing into a network, so called wire mesh.
2. Quantity and packing
Stainless steel material refers to air, steam, water and other weak corrosive medium and acid, alkali, salt and other chemical corrosive medium corrosion of steel, also known as stainless acid-resistant steel. In practical application, the steel that is resistant to weak corrosive medium is often called stainless steel, and the steel that is resistant to chemical medium corrosion is called acid resistant steel. And galvanized wire has good toughness and elasticity, the amount of zinc can reach 300 grams/square meter. It has the characteristics of thick galvanized layer and strong corrosion resistance. Products are widely used in construction, handicrafts, silk mesh, highway fence, product packaging and daily civilian and other fields.
The use of electric welding mesh is very widely, but also used in different industries, different places, many times the name is named because of the use or use, so the use of electric welding mesh is doomed to a variety of different names. Can be called row welding mesh, or zinc plating welding mesh or galvanized welding mesh. There’s also the outer wall wire, which is just used for insulation, usually placed on the outside of the wall, to reduce heat emission.
Galvanized wire is processed from low carbon steel wire rod, after drawing forming, pickling rust removal, high temperature annealing, cooling and other processes. Galvanized wire is widely used. Electroplating temperature should be controlled at 30 to 50℃. Because the chloride ions in the bath are very corrosive, quartz glass heaters are generally used.
If the zinc coating is good, but in 3% nitric acid when the light, the coating has dark shadow, passivation occurs when the film is brown, may be caused by foreign metal impurities such as copper or lead in the galvanizing liquid. When problems occur in the process of galvanizing large coil galvanized wire, the temperature and current density are checked first, and then the content of zinc and sodium hydroxide in the plating solution is measured and adjusted through the analysis of the plating solution. Whether DPE content is low can be determined by hull cell test.