Next, apply a small amount of grease to the seal lip(s) and the area of the shaft in contact with the seal. When using a double-lip seal, fill the small cavity between the two lips with grease as well. This both protects the lips during initial installation and break-in, and also acts as another barrier keeping contaminants out. When installing rubber-coated seals, apply lubricant to the outside diameter as well. This will help prevent the seal from rebounding or backing out from its mounting place.
As type C with dust lip
These types are made with a metal outer case and a PTFE lip. They are suitable for a wide range of temperatures from -90 °C to +260 °C.These lip seals can also be used for higher pressures of up to 10 bar (special types up to 25 bar) and rotational speeds of up to 40-45 m/s. Certain grades of PTFE are suitable for use in pharmaceutical and food applications. One important point is that PTFE lip seals do require a shaft with a harder, smoother finish.