Nestor rolling cage, high-speed railway Nestor rolling cage and railway Nestor rolling cage are all produced, sold and installed in accordance with the technical requirements of the reference drawing of railway line 2012-8001. Nestor rolling cage is a kind of protective equipment emerging in railway in recent years. Nestor rolling cage is connected by Nestor connecting clip on the longitudinal tensile rib fixed on the bracket. The longitudinal tension and the support are connected with the Φ2.5mm cold-drawn galvanized steel wire around 2 laps and then tightened. The support is set in the column and the middle of the span of the protective fence of 3m. The other spans are only set with the upper column, and the support and the protective fence are connected with the bracket hoop. For the protective fence that has been installed with metal mesh, the Nestor roller cage is directly fixed on the transverse sheet and wire of the metal mesh with the cold-drawn galvanized steel wire of 2.5mm or the Nestor connection fastener.
There are many categories of large coils of galvanized wire, and different categories can be applied to different scenarios. Galvanized iron wire common application is the application of the construction industry, one is the use of binding wire, whether it is the binding of scaffolding or reinforcement, need galvanized iron wire to carry out, the common specifications are 22 and 24 wire, common length of 30cm, 35cm, 40cm, 45cm, 50cm. There is also 20kg or 50kg a bundle of 18, 16, 14, 12, 10 galvanized coil wire.
Hexagonal guardrail net custom corrosion lost the original characteristics, in the shape, color and mechanical properties will change, resulting in equipment damage, pipeline leakage, etc., specifically, is prone to fracture, lose the original protection function. Usually there are three kinds of metal corrosion: physical corrosion, chemical corrosion, electrochemical corrosion, corrosion in addition to the chemical properties and organizational structure of the metal itself, but also related to the surrounding medium, such as wet environment than dry environment easy corrosion, more impurities than impurities less easy corrosion, high temperature conditions than low temperature conditions easy corrosion. After understanding these, we can effectively prevent the customized corrosion of hexagonal guardrail net and extend the service life of the product.
(1) The application method of packaging and binding galvanized shaft wire ordering: ① the pulling position on the goods should be reasonably selected. When used to avoid horizontal movement of goods, the pulling position should be as low as possible; When used to avoid overturning the goods, the pulling position can be appropriately high. ② The use of galvanized iron wire [1] pull reinforcement methods mainly include: figure eight, inverted figure eight, cross, zigzag or reverse zigzag and so on. Various pull methods can be used alone, but also two or more than two kinds of use. The pull should be as symmetrical as possible. (3) When pulling reinforcement, the single or double strands of galvanized iron wire will reciprocate around the goods and vehicles between the two tying nodes, and should be pulled tight galvanized iron wire so that the tightness of each strand is as common as possible, and some of the remaining cross around its own rope rod, and the rest of the tail toward the car.
Galvanized wire is divided into hot dip galvanized iron wire and galvanized iron wire according to the production process. It has the characteristics of high tensile strength, good softness, zinc layer uniformity, corrosion resistance, beautiful color, good smoothness, strong adhesion and corrosion resistance. Hot dip galvanizing has better protective properties than electric galvanizing, so it is an important protective coating for steel parts used in harsh working conditions.
The external environment has a great influence on the storage of cold drawn wire. Especially during the rainy season, special attention should be paid to the air humidity of workshops and warehouses. It is recommended to use moisture test paper with a value between 8 and 10. If the PH value is high, attention should be paid to the corrosion of the internal cold drawing wire. Cold drawing wire in normal environment storage for two years no problem, cold drawing wire will not be corroded. However, it is necessary to place the coil gently during the handling process to avoid the winding position leading to the cable is not smooth.
In order to improve the corrosion resistance of steel pipe, the general steel pipe is galvanized. Galvanized steel pipe is divided into hot dip galvanized and electric galvanized. The layer of hot dip galvanized is thick, the cost of electric galvanized is low, and the surface is not very smooth. Used for steel blowing oxygen pipe, generally with small diameter welded steel pipe, specifications from 3/8-2 inches of eight. Made of 08, 10, 15, 20 or 195-Q235 steel strip, in order to prevent corrosion, some should be aluminized.
In strict accordance with the multi-pass small compression rate drawing, the total compression rate is 96.48%, reducing the scraping of zinc layer. The whole wire drawing die is made of tungsten steel die and polycrystalline die. The Angle of the working cone of the wire drawing die is 12° ~ 16°, and the length of the sizing belt is 0.15 of the diameter of the wire, so as to ensure that the deformation of the zinc layer is basically synchronous with the steel wire substrate.
The use of bundled galvanized wire with the development of industry and agriculture also expanded accordingly. Therefore, galvanized wire products in the industry, such as chemical equipment, oil processing, Marine exploration, transport, electricity, shipbuilding, metal structure, etc.), agriculture (such as sprinkler irrigation, dim room, building (such as water and gas transport, wire casing, scaffolding, house, etc.), Bridges, shipping, etc., has been widely use in recent years. Because galvanized wire goods have beautiful surface, good corrosion resistance and other characteristics, its use scale is more and more extensive.
There are many categories of large coils of galvanized wire, and different categories can be applied to different scenarios. Galvanized iron wire common application is the application of the construction industry, one is the use of binding wire, whether it is the binding of scaffolding or reinforcement, need galvanized iron wire to carry out, the common specifications are 22 and 24 wire, common length of 30cm, 35cm, 40cm, 45cm, 50cm. There is also 20kg or 50kg a bundle of 18, 16, 14, 12, 10 galvanized coil wire.
Hook mesh is hooked flower machine (diamond mesh machine) for all kinds of metal hooks, can be divided into (lock, twist folding locked two. Data VC wire, stainless steel wire, low carbon steel wire, wire, galvanized wire. Based on entry, rhomboid net, rhomboid net, ring collection, chain net, collection, anchor net, hook breeding, playing net fence. Appearance disposal: according to electric galvanizing, hot dip galvanizing, plastic hook polyethylene plastic bag, dip plastic, spray plastic, hook mesh. According to the use: decorative hook (simple, guardrail, hook mesh, maintenance of another classification: stainless steel data 201,302,304 hook (left, 316, appearance disposal, none).
In order to remove defects such as surface film layer and surface inclusion of large roll galvanized wire, it can be treated by conventional technology. The presence of small homogeneous particles of large denier in the tank can stabilize the foam layer, but the accumulation of too many solid particles can cause explosion. Activated carbon mat to remove surface active substances, or through filtration to make the foam less stable, these are effective measures; Other measures should also be taken to minimize the intake of surface active substances. The electroplating speed can be significantly reduced by the introduction of organic matter.
There are two kinds of use, namely slope protection hook mesh, coal hook mesh, mining hook mesh, coal mine support network, roadway support network. The height of the outer rail of the pavement or seat belt should not be less than 1.10 m. The net distance between balustrade members shall not be greater than 140 mm, and horizontal rail shall not be used. Hook mesh planning is necessary to be safe and reliable, anchor should be installed on the basis of the railings, its strength should meet the requirements of the standard.